Zoombak ZB201 series Manuale Utente

Navigare online o scaricare Manuale Utente per Navigatori Zoombak ZB201 series. FIRE DETECTION Manuale Utente

  • Scaricare
  • Aggiungi ai miei manuali
  • Stampa
  • Pagina
    / 72
  • Indice
  • SEGNALIBRI
  • Valutato. / 5. Basato su recensioni clienti
Vedere la pagina 0
ELKRON. THE HI-PROTECTION COMPANY
FIRE DETECTION
Vedere la pagina 0
1 2 3 4 5 6 ... 71 72

Sommario

Pagina 1 - FIRE DETECTION

ELKRON. THE HI-PROTECTION COMPANYFIRE DETECTION

Pagina 3 - THE HI-PROTECTION COMPANY

CONVENTIONALFIRE DETECTIONSYSTEMSC/302 CONTROL UNIT ... pag. 13C/54 CONTROL UNIT ... pag. 14C/7000 CONTROL UNIT ...

Pagina 4 - THE FIRE ELKRON OFFER

Conventional fire detection system by Elkron is proved to be the ideal system for all the systems which do not need a large extent to be available.Anyh

Pagina 5

Control Unit C/302C/302 cod. SC6000121Single Zone central unit, with microprocessor in polycarbonate, suitable for controlling fire stop doors.Internal

Pagina 6

C/54 Control UnitC/54 cod. SC1800121Compact central unit, with microprocessor, suitable for small size fire and gas systems.Composed of a red plastic e

Pagina 7 - ALPHABETIC INDEX

Accessories for C/54 control unitMOD/54-R cod. SC2410121Module allowing C/54 central unit to increment and differentiate actuation control for each zo

Pagina 8

C/7000C/7000 cod. SC5200121Modular conventional fire detection central unit, with 16 bit microprocessor, 4 detection zones expandable up to 16.Software

Pagina 9

Accessories for C/7000 control unitSONG/54 cod. HS0910121Control module for siren line.INT-SONG/54 cod. HS1010121Intermediate control module for siren

Pagina 10

Optical heat detectorBP/212 T cod. SD8900121Low profile conventional optic heat detector with heat probe having 70° C intervention temperature.Correct

Pagina 11 - CONVENTIONAL

METHANE gas detectorBPG/213 CH4 cod. SD3300121Methane gas detector with semiconductor (semiconductor head FIGARO) ha-ving 2 intervention threshol

Pagina 13 - SINGLE ZONE CONTROL UNIT

ButtonsP445 cod. SB3500121Red alarm conventional pushbutton with breaking.Visual alarm repetition: red led•Alarm absorption: 20 mA @ 18 Vdc•Actuati

Pagina 14 - FOUR ZONE CONTROL UNIT

ADDRESSEDFIRE DETECTIONSYSTEMSAREA 54/1 ... pag. 23AREA 54/4 ... pag. 24AREA 54/8 ...

Pagina 15 - INT-SONG/54

A technological innovation from Elkron-Sira proposes a last generation multiprocessor fire analo-gue detection system. It is a system for all applicat

Pagina 16 - C/7000-R cod. SC5300121

AREA54/1L Control UnitAREA54/1L cod. SC3900121Analogue central unit, with 16 bit microprocessor, to manage fire systems with single detection line.It i

Pagina 17 - CONVENTIONAL DETECTORS

AREA54/4L Control UnitAREA 54/4L cod. SC1900121Modular analogue central unit, with multiprocessor, having 4 LOOPs max.The unit is provided with base w

Pagina 18

AREA54/8L Control UnitsAREA54/8L cod. SC4100121Modular analogue central unit, with multiprocessor, having 8 LOOPs max. The unit is provided with 1 MR/

Pagina 19 - BPG/213 GPL

AREA54/16L Control UnitAREA54/16L cod. SC3800121Modular analogue central unit, with multiprocessor, having 16 LOOPs max. The unit is provided with bas

Pagina 20 - CONVENTIONAL PUSH BUTTONS

Line ModuleMR/128 cod. SC2810121Addressable line module allowing to acquire, pilot and check a closed or open type detection line on which up to 128 a

Pagina 21 - ADDRESSED

ModulesSP/410 cod. SC2610121Analogue addressed multi-purpose interface allowing to control dry contact equipment or input for impulsive contac

Pagina 22 - AREA54/4

ModulesMCR/DIN-2000 cod. SC9110121Analogue addressed module with collective addressing. The module allows to manage a secondary line, made up of conve

Pagina 23 - AREA54/1L

THE HI-PROTECTION COMPANYAnother safe and secure day. Since 1974 Elkron has been committed to guarantee Security to any type of application, from smal

Pagina 24 - AREA 54/4L

ModulesISO/C cod. SC2210121Short-circuit analyser module for lines for analogue detections; the module is designed to ensure the operation of the dete

Pagina 25 - AREA 54/8L

Optical DetectorBPA/212 cod. SD3600121Low profile smoke optical addressed analogue detector. Visual operation signal is provided by two red leds placed

Pagina 26 - AREA 54/16L

Differential HEAT DETECTORBTA/206 cod. SD3400121Low profile maximum temperature thermo-speedometric and heat addres-sed analogue detector.Visual oper

Pagina 27

ButtonsP/430 cod.SB2200121Red alarm analogue pushbutton with recommissioning.Visual alarm repetition: red led•Dimensions (HxLxD): 110 x 110 x 42 mm•

Pagina 28 - MAS/DIN-2000

CentralisationMRS/232/485-DIN cod. SC9310121Module to convert signals from RS232 to RS485 allowing serial communi-cation between apparatuses up to 1,2

Pagina 29 - ISO/BASE

UNIVERSAL CONNECTION BASESDUCTEDDETECTION35

Pagina 30 - ISO/BASE-IP

ZB/200 cod. SD2700121Universal base for smoke and thermo-speedometric optical sensors for conventional analogue and digital systems.ZB/201 cod

Pagina 31 - BPA/212T

FAP500DIGITALSYSTEMFAP 54/1 ... pag. 40FAP 54/4 ... pag. 41FAP 54/8 ...

Pagina 32 - CONSOLLE/54

FAP500 SYSTEMFAP500 DIGITAL SYSTEMFrom Elkron research, FAP 500 series is born, i.e. a new smoke detection digital system.Within Elkron fire system the

Pagina 33 - BUTTONS FOR ADDRESSED SYSTEMS

FAP 500 SERIES CONTROL UNITSThe new control unit FAP544 is modular that is possible to expand the standard configuration with functions and peripher

Pagina 34

THE FIRE ELKRON OFFERCONVENTIONAL FIRE SYSTEMSSingle Zone central unit, with micro-processor in polycarbonate, suitable for controlling fire stop doors

Pagina 35 - DETECTION

FAP541 Control UnitFAP541 cod. SC6100121Microprocessor control unit with 1 loop lineConfiguration: 1 loop line (class A) or 2 open lines (class B)•Po

Pagina 36 - UNIVERSAL CONNECTION

FAP544 Control UnitFAP544 cod. SC6200121Microprocessor control unit with 2 loop lines expandable to 4Basic configuration: 2 loop lines (class A) or 4

Pagina 37

Expansion moduleFA128 cod. SC33101211 loop expansion moduleThe expansion module enables to expand the control unit by 1 loop line or •2 open lines.

Pagina 38 - FAP500 DIGITAL SYSTEM

AccessoriesSOFT/FAP500 cod. SW3500121Configuration SWThis software enables to acquire the system characteristics by reading •the control un

Pagina 39

RIVELATORI CONVENZIONALI Photo-optical smoke detectorFDO500 cod. SD4800121Low profile photo-optical smoke detector, complete with self-learning circuit

Pagina 40 - 1 LOOP LINE CONTROL UNIT

Thermo-speedometric detectorFDTD500 cod. SD9000121Low profile thermo-speedometric detector, complete with self-learning circu-it and short-circuit isol

Pagina 41

Standard baseSD500 cod. SD4K00121Digital detector standard base.The base is standard for all digital detectors of the FAP500 series.•Material: ABS•

Pagina 42

EXTINGUISHING CONTROLUNIT47

Pagina 43 - FAP500 SYSTEM: BUTTONS

EXTINGUISHINGCONTROL UNITEXTINGUISHING CONTROL UNITOUT 1OUT 2LOOP 1FMR500 FMR500FDT500 FDT500TM24IO500EXTINGUISHINGSYSTEMSREMOTECONTROLSWITCHUNBLOCKPU

Pagina 44 - FAP500 SYSTEM: DETECTORS

CDS cod. SC3600121Extinguishing control panel fitted with one module expandable to 2CDS extinguishing control panel is a non-expandable, 1 loop, microp

Pagina 45

THE FIRE ELKRON OFFERFAP500 DIGITAL FIRE DETECTION SYSTEMMicroprocessor control unit with 1 loop line. Possibility of managing up to 128 points for lo

Pagina 47 - EXTINGUISHING

GAS, LIQUIDS, HEAT AND LINEARDETECTORSAND CONTROLUNITSGAS DETECTION CONTROL UNIT pag. 52TOXIC AND EXPLOSIVES GAS DET. .. pag. 53FLAME DETECTOR ...

Pagina 48 - CONTROL UNIT

Gas Detection Control UnitsST/PL4 cod. SC6R00123Gas detection central unit allowing the connection of 4 minimum number to 8 maximum number of inflammab

Pagina 49 - EXTINGUISHING CONTROL UNIT

Accessories for ATEX control unitsSTG/IN8 cod. SC9R10123Remote module for 8 board inputsSTG/OUT16 cod. SC1S10123Remote module for 16 open collector pr

Pagina 50

GAS DETECTORS, EX II 3GD TYPES2096ME cod. SD9S00123Methane gas detector 4-20 mA, 0-100% LELCatalytic sensor: Nemoto.•Absorption: 130 mA@12Vcc. •S170

Pagina 51

GAS DETECTORS, Ex II 2GD TYPES2097VB cod. SD1U00123Petrol vapours detector 4-20 mA, 0-100% LELCatalytic sensor: Nemoto.•Absorption: 130 mA@12Vcc.•S2

Pagina 52 - STG/MTSLB

Accessories for gas detectorsST/S3REL cod. SC5R10123Board with three relays for gas detectors. It allows to have contacts free from voltage. •The fir

Pagina 53 - EX II 3GD

Liquid detectorRA/209 cod. SD2B00121 Electronic detector to detect the presence of (uninflammable) liquids. Detecting the presence of water is through

Pagina 54 - DETECTORS AND CONTROL UNITS

Heat detectorRTS/4 cod. SD4C00123IP55 heat detector based on the deformation of a bimetallic element which closes a dry contact as the temperature is

Pagina 55 - EX II 2GD

Heat DetectorRLB/1 cod. SD6P00121 Linear heat detector, 68°C calibration (certified)Packaging: 100 m skein•RLB/2 cod. SD5P00121 Linear heat detector,

Pagina 56 - INFRARED FLAME DETECTOR

THE FIRE ELKRON OFFERSPECIAL HEAT DETECTORPAGE57IP65 Special heat detector based on the deformation of a bimetallic element which closes a dry co

Pagina 57 - SPECIAL HEAT DETECTOR

Fire and smoke linear detectorsSF-100 + INT8C cod. IL1400123 Fire and smoke linear detector.The system includes three units: Transmitting unit (TX), R

Pagina 58

AccessoriesINT8C/24V cod. IL1010123 Interface module allowing the connection and operation of the Tx and Rx units of smoke linear detector.

Pagina 59 - LINEAR DETECTORS

ASD cod. SC2R00123Aspirating single-pipe sampling unit. For PVC/ABS ø 3/4” pipe, max pipe length: 100 m. Power supply: 24Vdc, •smoke detectors not i

Pagina 60

OPTICAL-ACOUSTIC INDICATORSPOWER SUPPLYBATTERIESPANELS ... pag. 64OPTIC REPEATER ... pag. 66BEL

Pagina 61 - INT8C/24V

Optical Acoustic PanelsTM24 cod. FH2600121Optical/acoustic signalling single face panel•Power supply : 12 – 24 Vdc•Max consumption: 100 mA•Light

Pagina 62 - FIRE TRACER

Optical Acoustic PanelsTM224 cod. FH310012124Vdc self-powered optical/acoustic signalling double face panelPower supply : 24Vdc•Max consumption:

Pagina 63 - BATTERIES

Outdoor visual repeatersLR500 cod. SR1100121Outdoor visual repeaterVisual repeater allowing to show the alarm status of a detector installe

Pagina 64 - OPTICAL-ACOUSTIC INDICATORS

Bells4476/24 cod. HS7300123 Bell with classic appearance for fire alarm systems and other warnings. The internal movement with motor, pinion and strike

Pagina 65

HP500F cod. HS5000121 Outdoor red self-powered siren made in die-cast aluminium.Provided with signalling flash with incandescent lamp.Operation voltag

Pagina 66 - VISUAL REPEATERS

EXPLOSION PROOFDEVICESEXPLOSION PROOF DEVICESP/406 cod. SB3000121Manual fire alarm pushbutton, with explosion-proof casing, for areas with potentia

Pagina 67 - ELECTRONIC BELLS

ALPHABETIC INDEXPRODUCT’S NAME CODE PAGE PRODUCT’S NAME CODE PAGE1370/15 MM7100123 681370/30 MM7300123 681469 SB4600123 20147

Pagina 68 - ELECTROMAGNETS

POWER SUPPLY UNITSAND BATTERIESPOWER SUPPLY UNITS AND BATTERIES82425 SBG cod. PS7900123Power supplier with 27.6 V output voltage in switching version

Pagina 71

ALPHABETIC INDEXPRODUCT’S NAME CODE PAGE PRODUCT’S NAME CODE PAGEP 440 SB380 0121 19PICO SC3R00123 62PUNTO/54 S W310 0121 34R/

Pagina 72

CONVENTIONALFIRE DETECTIONSYSTEMSC/302 ........13C/54 .........14C/7000 .......16DETECT

Commenti su questo manuale

Nessun commento